Description / Abstract:
These procedures cover the following:
Paragraph 3 - Cone end connections for flared tube and brazed
ferrule, with and without gasket.
Paragraph 4 - Boss end connections, positioned type, with
back-up ring.
Paragraph 5 - Boss end connections, positioned type, without
back-up ring
Paragraph 6 - Boss end connections, non-positioned type.
Paragraph 7 - Bulkhead connections.
Purpose
To establish standard installation procedures for fluid
connection parts listed in this standard.
All parts with lockwire holes shall be lockwired per AS567.