Description / Abstract:
This interface standard applies to fuzes/fuzing systems
(referred to as fuzing system hereafter) in airborne weapons that
use a MIL-STD-1760 type interface. It defines the powers, the
discrete signals and the serial data interface for the
communications at the interface between the fuzing system and the
remainder of the weapon, including the weapon control unit.
The Class 1 interface is an electrical only interface that
facilitates use of MIL-STD-1760 type platform store interfaces for
the fuze to monitor intentional release and defines the fuze
interface bus communications protocol to allow sending and
receiving data from fuzing systems.
Class 2 interfaces add a defined connector and additional
interfaces to facilitate the exchange of compatible fuzing
systems.
Class 3 interfaces add further interface definitions to
facilitate the exchange of AS5680A compatible fuzing systems
components.
The bus communications protocol provides a means by which the
weapon may set mission parameters within the fuzing system main
housing and in other devices external to the fuzing system main
housing. The standard also defines the target detection signal to
be provided by a target detection device external to the fuzing
system.
This standard does not address the mechanical interfaces to
target detection devices or to other sensors that are external to
the fuzing system main housing.