Description / Abstract:
This SAE Standard defines the test conditions, procedures, and
performance requirements for circuit breakers in ratings from 50 to
200 A. This document covers automatic reset, modified reset and
manual reset types of circuit breakers for low voltage DC systems
(12 V and 24 V).
NOTE-It is technically feasible for circuit breakers in this
general class to be provided in amperage ratings below 50 A. In
those instances, the procedures as detailed herein may be used
provided compensation is made for test currents, test leads, and
power supply requirements. Additional guidance may be obtained from
SAE J553 - Circuit Breakers.
Operational requirements for 42V vehicular electrical systems
are under development as of this revision. The electrical
environment is not completely defined, particularly as it relates
to other components that would influence circuit breaker function
(such as storage battery technology, charging system design and
operational characteristics). The test and evaluation requirements
of this standard are sufficient to determine relative performance
concerning current carrying capability, environmental durability,
and general requirements regardless of maximum voltage rating. It
is anticipated that a separate technical document will be created
to capture requirements unique to 42V electrical system
architecture and load characteristics.