Description / Abstract:
This SAE Standard sets forth measurements procedures and
instrumentation to be used for determining a "representative" sound
level during a representative time period at selected measurement
locations on a construction site boundary. The document is not
intended for use in determining occupational hearing damage risk.
Determination of a representative time period is left to the
judgment of the user.
Purpose
The purpose of this SAE document is to set forth procedures that
may be used by construction site management for self regulation and
construction site planning or by state and local officials for the
enforcement of construction site noise regulations. Two measurement
methods are provided to obtain the time-integrated equivalent sound
level, leq, emitted by construction site activity. First, a
sampling procedure is recommended for use with a sound level meter.
Second, a measurement procedure using an integrating sound level
meter is presented. The latter procedure is generally preferred.
Use of this document provides sound level data representative of
the complex time-varying sounds emitted by construction activities,
which may be used to estimate community reaction to the
construction activity.