Description / Abstract:
This document establishes techniques for validating that a
mission store complies with the interface requirements contained in
MIL-STD-1760 Revision D.
Purpose
The purpose of this document is to provide methods for
validating that a mission store's electrical interface complies
with the mission store interface (MSI) requirements of
MIL-STD-1760. This document provides a set of modular, independent
methods covering each of the requirements placed on the store by
MIL-STD-1760. The methods contained herein apply to both the
primary and auxiliary interfaces of MIL-STD-1760.
Application
The methods herein apply to the initial validation of a store
design to the requirements of MIL-STD-1760 and are expected to be
conducted as part of store design validation as opposed to
qualification test, conformance test, flight-line test, etc. The
methods contained in this document are sufficient to encompass the
Class I interface. Mission stores with Class II MSIs will use the
appropriate subset of these Class I methods.
Tailoring
The methods contained herein are general methods for conducting
mission store validation and, as such, do not provide detailed
procedures for these methods. It is intended that detailed
procedures for validation of a specific mission store will be
covered by tailored test plans and procedures prepared specifically
for that store. These tailored test procedures would, for example,
address those store-specific commands required to step through
sufficient operations and states to demonstrate compliance with the
particular aircraft/store electrical interconnection system (AEIS)
requirement under test.
Limitations:
The methods contained herein are based on MIL-STD-1760. This AS
is based on the assumption that all tests are conducted at the
store's MSI connector and measurements of store performance occur
only at this MSI connector.